Build Your Online Product Catalogs?
Product Name: |
solid state decoupler transformer
|
Supply Ability: |
15000sets |
Related proudcts |
transformer, solid state, |
Specifications |
QOH-1 solid state decoupler |
Price Term: |
FOB,CIF |
Port of loading: |
Fuzhou,Xiamen |
Minimum Order |
1set |
Unit Price: |
|
|
1 Product uses Decoupler is a AC Interference protection product, which sets Embedded-type line flowing and surge protector in one. It is mainly used in long-distance buried pipeline engineering. As following situations: high-tension transmission line tower and communication tower and their ground system which near the pipeline; public passage between high-tension transmission line and pipeline; cross of pipeline and transmission line or Electrified railway-parallel pipe; the installation of the decoupler can reduce the influence of DC, AC & stray current or thunder flow on the buried pipelines, also strengthen stability of pipeline cathodic protection potential. 2 Codes and Standards ¡ªGB/T2423.1 Environmental testing - Part 2: Test methods -Tests A: Cold. ¡ªGB/T2423.2 Environmental testing - Part 2: Test methods -Tests B: Dry heat. Ò»GB/T2423.3 Environmental testing for electric and electronic products - Part 2: Testing method - test Cab: Damp heat Steady state. ¡ªGB/T2423.5 Environmental testing for electric and electronic products Part 2:Test methods Test Ea and guidance: Shock. Ò»GB/T2423.10 Environmental testing for electric and electronic products - Part 2: Test methods Test FC and guidance: Vibration (Sinusoidal). Ò»GB11032 Metal-oxide surge arresters without gaps for a.c. Systems; ¡ªGB4208 Degrees of protection provided by enclosure(IP code); ¡ªGB 18802.1/1 EC 61643-1 Surge protective devices connected to low-voltage power distribution systems--Part 1: Performance requirements and testing methods Ò»SY/T 0032 Standard for AC influence drainage protec tion of buried steel pipeline. 3 Main technological performance 3.1 Environmental parameter Operating environment: -45'tD~+65cC Relative humidity: 20%90%RH 3.2 The insulation resistance between the terminals and the box should be not lessthan 20MQ. 3.3 The maximum lightning shock(8/20 M S) current that the decoupler can be tolerated should be not less than 100KA. 3.4 The maximum fault current that the decoupler can be tolerated should be no |
Company: |
Fujian Changlian Electronic Co., Ltd
|
Contact: |
Ms. haley lai |
Address: |
No.17 Jingdong Industry Park Sanyuan District |
Postcode: |
|
Tel: |
86 0598 8808628 |
Fax: |
0598-8806628 |
E-mail: |
|
|
|
|